Resettable Emergency Door Release Button | NO/NC/COM Exit Switch

Resettable Emergency Door Release Button | NO/NC/COM Exit Switch

🔥 1 sold✓ In stock
Regular price HK$65.00
Regular price Sale price HK$65.00
Sale Sold out
Shipping calculated at checkout.
Quantity

Short Product Description

Ensure absolute safety in your building with theResettable Emergency Door Release Button. Designed as a critical failsafe for access control systems, this fireproof exit switch instantly cuts power to magnetic locks or electric strikes if your card reader or controller fails during an emergency. Featuring a clear protective cover to prevent accidental triggers and a reusable resettable mechanism, it eliminates the need for replacement glass. Need help wiring your security system?Sun Cheong Computer Co. Ltd.has over 20 years of IT and security expertise. Visit our Sham Shui Po physical store for instant pickup and expert on-site technical configuration support!

Key Features

  • Instant Override: Physically cuts power to electric locks, ensuring doors open immediately during hardware failures or emergencies.
  • Resettable Mechanism: Reusable design eliminates the need for replacement glass; simply use the key to reset the switch after activation.
  • Clear Protective Cover: Prevents accidental triggers and false alarms in high-traffic areas while remaining easily accessible.
  • Universal NO/NC/COM Outputs: Compatible with all types of access control systems, fail-safe magnetic locks, and fail-secure electric strikes.
  • Fireproof Material: Constructed with flame-retardant plastics to withstand harsh conditions and meet building safety requests.
  • High Current Rating: Safely handles up to 3A at 36VDC, making it suitable for heavy-duty security hardware.

Full Product Description

The Ultimate Failsafe for Access Control Systems

In any commercial building or secure facility, safety must always come first. If an access control panel, RFID reader, or exit button malfunctions during a power surge or emergency, personnel can become trapped inside. The Resettable Emergency Door Release acts as a direct, hardwired override. By pressing the panel, it physically breaks the electrical loop to your door locks, instantly releasing magnetic locks or electric drop bolts to ensure a safe and immediate exit.

Reusable Design Saves Time and Money

Traditional "break glass" call points require you to purchase and install replacement glass every time they are triggered or accidentally bumped. This modern emergency switch features a resettable plastic mechanism. Once activated, the front plate drops down to cut the circuit. To restore the system, simply use the included reset key to pop the plate back into its original position. It is 100% reusable, saving maintenance time and operational costs.

Fireproof Construction with Protective Cover

Built to meet strict safety requests, the entire housing is constructed from premium fireproof materials with an elegant sandblast finish. To prevent false alarms or accidental triggers by passing carts or personnel, this model comes equipped with a clear hinged protective cover. Users must lift the cover before pressing the emergency release, adding a crucial layer of intentionality to the activation process.

💡 Pro Tip from Our Technicians

"Wiring an emergency release correctly is critical for life safety. If you are using a fail-safe lock (like a standard magnetic lock that requires power to stay locked), you must wire this switch in series using the COM (Common) and NC (Normally Closed) terminals. When pressed, it breaks the circuit, dropping power to the lock. If you are building a custom access control system and aren't sure how to wire this into your power supply controller, drop by our Sham Shui Po store! Our team at Sun Cheong Computer Co. Ltd. will map out the exact wiring diagram for you on the spot."

Technical Specifications

Specification Details
Product Type Resettable Emergency Exit Release (Call Point)
Dimensions (L x W x H) 86 mm x 86 mm x 56 mm (Excluding Cover)
Current Rating 3A @ 36VDC Max
Output Contacts NO / NC / COM (Normally Open / Normally Closed / Common)
Material Fireproof Plastic, Sandblast Finished
Protective Feature Clear Hinged Protective Cover Included
Suitable For Exit Doors, Emergency Doors, Access Control Systems
Operating Temperature 10°C to +55°C (14°F to 131°F)
Operating Humidity 0 - 95% (Non-condensing)
Weight 0.2 kg

Delivery Options

  • Local delivery within Hong Kong and in-store pickup.​
  • Free shipping for orders of HK$400 or above; HK$35 shipping fee for orders below HK$400.​
  • Shipped by SF Express, usually dispatched the same day for orders confirmed before 6:00 PM (Mon–Sat).​
  • Estimated delivery time: 1–3 business days after dispatch (Hong Kong).​
  • In-store pickup details (location and time) will be confirmed by email or phone message.​
  • Delivery times are estimates and may be affected by weather or unforeseen circumstances.​

FAQ Section

  • How do I reset the button after it has been pressed?Unlike traditional break-glass models, this resettable switch comes with a special reset key. Simply insert the key into the designated slot on the unit, and the front faceplate will pop back up into its original, armed position, restoring the electrical circuit.
  • Does this button need its own power supply to work?No, this emergency release button is a passive mechanical switch. It does not require its own power source. It acts as a bridge (or a break) in the power wire that goes from your access control power supply to your electric lock.
  • Can I use this with a 12V or 24V magnetic lock?Yes, absolutely. The internal microswitch is rated to handle a maximum of 3A at 36VDC. This makes it perfectly safe and compatible with standard 12VDC and 24VDC magnetic locks and electric strikes.

Target Users / Applications

  • Commercial Security Installers: Integrating reliable, code-compliant emergency overrides for office glass door magnetic locks.
  • Server Room Administrators: Ensuring IT staff can always exit secure data centers even during total access control panel failures.
  • Residential Building Managers: Upgrading old break-glass exits in apartment lobbies to reusable, resettable models to reduce maintenance costs.