Type-C Fast Charge UPS Power Supply / 18650 Lithium Battery Charger Module DC-DC Step Up Booster Converter 5V 12V
Function description:
1. UPS function: When the power supply is powered on, the power supply directly supplies power to the load via the booster circuit, and simultaneously charges the lithium battery. Once the power is cut off, the battery path is automatically activated to supply power to the load via the boost circuit.
2. Boost circuit: peak power up to 20W, rated power up to 15W, BOST boost circuit, built-in 12A high current MOS, efficiency up to 96%, module static power consumption 25mA, optional 5V/12V output. (The load is recommended to be <15W under normal conditions. Output 5V: current 2A, output 12V: current 1A)
3. Lithium battery protection: over-charge, over-discharge, over-temperature, over-current protection (if it enters the protection state and does not output after a short-circuit by mistake, it will automatically activate and restore output when connected to 5V charging).
4. Module size: 89*42*22.4mm (back patch battery box)
Instructions for use:
1. When used as a UPS, it is necessary to install a battery to ensure that the input 5V power supply has sufficient power, and the output is kept on in real time, and the battery can be started at any time when the power is off.
2. If the UPS wants to save energy consumption, solder down the output indicator after all tests are completed, which can reduce the current consumption of more than ten mA without affecting the normal output of the circuit, which is more power-saving.
3. During the use and operation, the board may be triggered to enter the protection state without output due to various reasons (incorrect touch, wrong connection, etc.). After troubleshooting, connect the board's charging port to 5V for charging, and the board is powered on again. Re-output can be activated.
4. The 5V charging power supply used by individual users uses a relatively large output capacitor. This capacitor can continue to discharge after the power is turned off, so that the power supply voltage has a slow drop process, which will cause the board after the power is turned off. Did not switch battery power quickly. If you encounter such a situation, you can connect a 1K discharge resistor in parallel to the 5V input port.
5. If you want to increase the battery capacity of the UPS module, you can use multiple cells in parallel, and other functions will not be affected.